ET Testsystem
|
Electronic AC Source EAQ-M
|
 |
For the complete line simulation of all technical
networks from DC - 2000 Hz
Technique pure
The highly precise electronic AC source meets all your demands. The
simulation of all technical lines as well as the measurement of the line
characteristics is its strength. The high efficiency of the electronic
AC source EAQ-M lies in the convincing technical data and the easy handling.
Besides the CV- and CC-modes, there is power up to 6000 VA, voltages up
to 1000 V AC, currents up to 120 A and frequencies up to 2000 Hz available.
On one Hand Simulation on the other Analysis
- CV- and CC-Mode !
- AC Voltage 0..300 Vrms (500V)
- DC Voltage 0..425 Vdc (700V)
- Frequency DC, 1 - 500 Hz (2000 Hz)
- Phase-triggered-switch on-and off
- External Oscillator inputo RS 232- Interface, IEEE 488 (option)
- Measurement Vrms V, Crms A, Cpeak A, Power W, Frequency Hz
| Short specification EAQ-M 1- phase Electronic AC
Source |
| Type |
Power |
VA Voltage V |
Current Arms/Peak |
Phases |
| EAQ-M-50 |
50 VA |
0...300Vrms / 425 Vdc |
0.20A/ 1.4 A |
1 |
| EAQ-M-250 |
250 VA |
0...300Vrms / 425 Vdc |
1.00A/ 4.0 A |
1 |
| EAQ-M-500 |
500 VA |
0...300Vrms / 425 Vdc |
4.00A/16.0 A |
1 |
| EAQ-M-750 |
750 VA |
0...300Vrms / 425 Vdc |
6.00A/20.0 A |
1 |
| EAQ-M-1000 |
1000 VA |
0...300Vrms / 425 Vdc |
8.00A/30.0 A |
1 |
| EAQ-M-1500 |
1500 VA |
0...300Vrms / 425 Vdc |
0.00A/40.0 A |
1 |
| EAQ-M-2000 |
2000 VA |
0...300Vrms / 425 Vdc |
15.00A/60.0 A |
1 |
| EAQ-M-3000 |
3000 VA |
0...300Vrms / 425 Vdc |
20.00A/80.0 A |
1 |
| EAQ-M-4500 |
4500 VA |
0...300Vrms / 425 Vdc |
30.00A/100.0 A |
1 |
| EAQ-M-6000 |
6000 VA |
0...300Vrms / 425 Vdc |
40.00A/120.0 A |
1 |

|
Motor Controlled AC Source EAQ-MT
|
 |
For line simulation of 1- and 3- phase networks
The Cost Reduced Solution at High Power
- CV Mode
- AC Voltage 0...270 Vrms (500 V)
- Performances up to 50000 VA !
- Fast Response Times typ. 100V/Sek.
- Adjustable Overcurrent Switching-off
- RS 232 / IEEE 488 Interface (Option)
- Measurements Vrms V, Crms A
- Switching-on and off via relay (Option)
The AC sources of the series EAQ-MT have been developed for the simulation
and analysis of one- or three-phase line voltage particularly for high
power. The output voltage is infinitely variable between 1 and 100% of
the nominal voltage and is being kept constant with a deviation of <
1%. The preset reference input can be reached with the potentiometer as
well as via the optional interfaces. In 3-phase units the regulation is
controlled by phase L1. The structure of the AC source EAQ-MT consists
of a regulated ring transformer with isolation. The regulated ring transformer
is operated through a DC motor. The set voltage is being kept constant
at deviations of the line input voltage as well as at load variations
at the output.
| Short specification EAQ-MT 1- Phase AC Sources |
| Type |
Power max VA |
Voltage Vrms |
Current Arms |
Phases |
| EAQ-MT-2708 |
2160 VA |
3...270Vrms |
8.0 A |
1 |
| EAQ-MT-27016 |
4320 VA |
3...270Vrms |
16.0 A |
1 |
| EAQ-MT-27020 |
5400 VA |
3...270Vrms |
20.0 A |
1 |
| EAQ-MT-27025 |
6750 VA |
3...270Vrms |
25.0 A |
1 |
| EAQ-MT-27030 |
8100 VA |
3...270Vrms |
30.0 A 1 |
1 |
| EAQ-MT-27035 |
9450 VA |
3...270Vrms |
35.0 A |
1 |
| EAQ-MT-27040 |
10800 VA |
3...270Vrms |
40.0 A |
1 |
| EAQ-MT-27050 |
13500 VA |
3...270Vrms |
50.0 A |
1 |
| EAQ-MT-27065 |
17550 VA |
3...270Vrms |
65.0 A |
1 |
Brochure ET-Testsystem
EAQ-MT

|
Line simulator EAQ-TIP
|
 |
For the complete line simulation of all technical
networks from DC - 2000 Hz
- V- und C-constant !
- AC Voltage 0..300 Vrms (500V)
- DC Voltage 0..425 Vdc (700V)
- Frequency DC, 1 - 500 Hz (2000 Hz)
- Phase Triggered ON- and OFF-Switching
- External Oscillator Inputo RS 232- Interface , IEEE 488 (Option)
- Measurements Vrms V, Crms A, Cpeak A, Power W, Power VA, Freq. Hz,
Cos Phi
The comfortable handling of the line simulator EAQ is possible with the
new Tipturn E control system. A clearly arranged LCD display offers a
view of all necessary parameters, such as measured values, limit values,
etc.. With only one button all functions are adjustable via an easy menu
selection. Standard is the integrated Centronics Interface on which a
printer can be connected without any special software. All measured values
can be transferred to another computer via RS232. The functions of the
simulators can be manual or in a stored automatic-test procedure. An automatic
self-test after switching on belongs to the standard achievement as well
as a user defined setting.
| Short specifikation EAQ-TIP 1- phase line simulators |
| Type |
Power VA |
Voltage V |
Current Arms/Peak |
Phases |
| EAQ-TIP-50 |
50 VA |
0...300Vrms / 425 Vdc |
0.20A/ 1.4 A |
1 |
| EAQ-TIP-250 |
250 VA |
0...300Vrms / 425 Vdc |
1.00A/ 4.0 A |
1 |
| EAQ-TIP-500 |
500 VA |
0...300Vrms / 425 Vdc |
4.00A/16.0 A |
1 |
| EAQ-TIP-750 |
750 VA |
0...300Vrms / 425 Vdc |
6.00A/20.0 A |
1 |
| EAQ-TIP-1000 |
1000 VA |
0...300Vrms / 425 Vdc |
8.00A/30.0 A |
1 |
| EAQ-TIP-1500 |
1500 VA |
0...300Vrms / 425 Vdc |
0.00A/40.0 A |
1 |
| EAQ-TIP-2000 |
2000 VA |
0...300Vrms / 425 Vdc |
15.00A/60.0 A |
1 |
| EAQ-TIP-3000 |
3000 VA |
0...300Vrms / 425 Vdc |
20.00A/80.0 A |
1 |
| EAQ-TIPM-4500 |
4500 VA |
0...300Vrms / 425 Vdc |
30.00A/100.0 A |
1 |
| EAQ-TIP-6000 |
6000 VA |
0...300Vrms / 425 Vdc |
40.00A/120.0 A |
1 |
Brochure
ET-Testsystem EAQ-TIP

Kikusui
|
PCR-L/ series
Multi-Purpose AC Power Supply
|
 |
- Liner-amp type
- AC:1 to 150/2 to 300V, 1 to 999.9Hz
DC:1.4 to 212/2.8 to 424V
- 1Ø, 500VA: PCR500L
- 1Ø, 1000VA: PCR1000L
- 1Ø, 2000VA: PCR2000L
- 1Ø, 4000VA: PCR4000L
- 1Ø, 6000VA: PCR6000L
- 1Ø, 8000VA: PCR8000L
- 1Ø, 12000VA: PCR12000L
- 1Ø, 18000VA: PCR18000L
Brochure
Kikusui PCR-L

|
PCR-W/W2 series
High efficiency AC Power Supply
|
 |
- PWM inverter type
- AC:1 to 150/2 to 300V, 1 to 500.0Hz
- DC:1.4 to 212/2.8 to 424V
- 1Ø, 2KVA: PCR2000W
- 1Ø, 4KVA: PCR4000W
- 1Ø, 8KVA: PCR8000W
- 1Ø, 12KVA: PCR12000W
- 1Ø or 3Ø selectable, 6KVA: PCR6000W2
- 1Ø or 3Ø selectable, 12KVA: PCR12000W2

|
|