Burster
|
High Precision Calibration Source for Voltage, Current and ThermocoupleDIGISTANT®
Model 4462
|
 |
- High precision current and voltage source± 52 mA, ±
30 V
- Precision simulation for all conventional thermocouple types (optional)
- Basic accuracy 0.005 % of reading
- RS232- and optional IEEE488 interface
Application
The precision calibration unit combines high accuracy, low drift, low
noise and superior long-term stability with multiple functionality and
simple operation.Ramps, delta + / delta -, and multiple setpoint storage
make the operation of the device easier for the user. For that reason
the application possibilities are many:
- Testing current and voltage meters Precise testing of thermocouple
temperature measuring instruments
- Calibration of controllers, sensors, detection devices and other devices
used in process control
- Open-loop process control with the aid of integrated ramp functions.
The DIGISTANT ® type 4462 can be used both as a stand-alone
table-top device, as well as in automatic, computer-assisted manufacturing
and testing systems.
Description
It is possible to set currents of ± 200 nA ... ± 52 mA,
voltages of ± 1µV ... ± 30 V and, optionally, temperature
setpoint values of 14 thermocouple types.The output value is fed back
via the sensor line to eliminate voltage drops across the measuring leads.The
device has an adjustable current/voltage limitation. An external voltage
divider of 1 up to 1:1000 can be considered internally.With the thermovoltage
sourcing option you can enter °C, °F and K, the temperature scales
ITS 90 or IPTS 68 and the comparison point mode constant/external. Furthermore,
when sourcing thermocouples a calibrated external comparison point can
be used, whereby the data for calibration in the device can be taken into
consideration.Indication of the source value is carried out in large 12
mm figures on an illuminated graphics-LCD.The device can be operated both
via the keyboard as well as the interface.
Brochure
Burster 4462

Wens
|
WENS 30C
|
 |
- 4 1/2digits Large display and simple, quick-click interface for easy
one-hand operation
- Simultaneous mA and % readout for quick, easy interpretation of
readings
- ㎃ accuracy of 0.025%
- 1㎂ resolution for mA source, simulate and measures
- Push button 25% steps for fast, easy linearity checks
- 24 volt internal loop supply, so you can power and read a
transmitter at the same time with a DMM
- Innovative output adjustment dial with 1㎂ and 100㎂ resolution
- power : 9V
Brochure
Wens 30C
|
|