Electronic Load / Elektronisk Konstlast                              Go to Ferner


Suppliers/ Leverantörer:

 

 


Kikusui

PLZ-4 series
Multifunctional Electronic Load (CC/CV/CR/CP)

  • Capable to work with constant-current, constant-resistance, constant-voltage, constant-power, and combination of constant-current + constant-voltage, constant-resistance + constant-voltage mode
  • Rise time: 10µs (which converts to rise and fall times) high-speed response
  • 0V input operating voltage type is available (PLZ164WA, PLZ664WA)
  • Achieving a large capacity system using the booster unit (PLZ2004WB)

Brochure Kikusui PLZ-4 series


 

PLZ-3W/3WH series
System Electronic Load (CC/CV/CR/CP)

  • Ready for constant current, constant resistance, constant voltage, and constant power modes
  • Capable of doing actual-load simulations under sequence control
  • Maximum input voltage of 500V (PLZ-3WH Series)
  • 8 models (150W/300W/600W/1000W)

Brochure Kikusui PLZ-3 series



PLZ152WA
Electronic Load (CC/CR)


  • Two currents can be set. Static or dynamic operation is easily performed using an external oscillator.
  • Accommodated to zero volts input
  • 150W

Brochure Kikusui PLZ152WA


ET Testsystem

Constant current and resistance regulationVoltages

60 - 500 Vdc
Currents 1 - 1000 A
Power from 100 - 20000W

The Electonic Load for Laboratory and System Applications

  • R- and C-constant !
  • DC Voltage up to 500 Vdc
  • DC Currents up to 1000 A
  • Powers up to 20 kW
  • Pre-setting functions
  • Up to 500 W also deliverable as 3 U/42TE Euro cassette
  • RS 232- Interface , IEEE 488 (Option)
  • Analogue Interface

The electronic load ESL-M is one of the most modern version of the outdated sliding resistor. The modes of operation current- and resistance constant guarantee continuously and electronically controlled load of an output on a supply mains, an electric circuit, a battery etc.. The C-preset
function offers the particular conveniences to pre-set the current values at the potentiometer and to read voltage and current from the two 3 ½ digits displays. The output will be activated only by operating the Stand-By key. Optionally the programming and measuring may follow via the analogue, RS232 and IEEE488 interface.

Show product specification and describtion




Load simulator EDL-TIP with Tipturn E

For the complete load simulation static and dynamic of DC - 2000 Hz Up to 1000 A/500V DC
Automatic long term observation
Recording
Data storage

 

Innovation EDL-TIP

More than just a simple load - the new Load Simulator EDL-TIP. With the comfortable input system Tipturn E (registered trademark at the patent office), the Load Simulator is a small test system with an infinity of efficient functions.

The Innovative Load Simulator

  • R-, C-, V- and P- constant !
  • Dynamic functions :
    - 1...2000Hz square wave
    - Duty Cycle 5-95%
  • DC voltage up to 500 Vdc
  • DC current up to 1000 A
  • Power up to 20 kW
  • RS 232- Interface , IEEE 488 (Option)

The new load simulator series EDL has got almost all technical realisable load simulations and is still very low-priced. The load simulator EDL represents basically a system of Tipturn E (the programming unit), load simulator, digital multimeter, data storage and the cabling and establishes therefore its high efficiency. The four operating modes constant-, current, resistance, voltage and power are completed through the dynamic function. The curve shape can adjusted between square, triangle and sine wave. The Duty Cycle, the frequency as well as the time of rise of current can be set. In addition to the different operating modes the simulator has got a number of mode- and long-term observation programmes (Burn In). The extensive standard programme in various types through the easy, optional choice of different voltage and current classes.

Short specification EDL-TIP

Type Power Voltage Vdc* Current Adc* Case
EDL-TIP-100 100 W 1....60 Vdc 0......20 A G2
EDL-TIP-250 250 W 1....60 Vdc 0......30 A G2
EDL-TIP-500 500 W 1....60 Vdc 0......50 A G2
EDL-TIP-750 750 W 1....60 Vdc 0......75 A G2
EDL-TIP-1000 1000 W 1....60 Vdc 0....100 A G2
EDL-TIP-1500 1500 W 1....60 Vdc 0....125 A G2
EDL-TIP-2000 2000 W 1....60 Vdc 0....150 A G5
EDL-TIP-3000 3000 W 1....60 Vdc 0....200 A G5
EDL-TIP-4000 4000 W 1....60 Vdc 0....250 A G6
EDL-TIP-5000 5000 W 1....60 Vdc 0....300 A G6
EDL-TIP-6000 6000 W 1....60 Vdc 0....350 A G8
EDL-TIP-7000 7000 W 1....60 Vdc 0....400 A G9
EDL-TIP-8000 8000 W 1....60 Vdc 0....500 A G9
EDL-TIP-9000 9000 W 1....60 Vdc 0....550 A G11
EDL-TIP-10000 10000 W 1....60 Vdc 0....600 A G11
EDL-TIP-12000 12000 W 1....60 Vdc 0....700 A G11
EDL-TIP14000 14000 W 1....60 Vdc 0....800 A G12
EDL-TIP-16000 16000 W 1....60 Vdc 0....900 A G13
EDL-TIP-18000 18000 W 1....60 Vdc 0....1000 A G13
EDL-TIP-20000 20000 W 1....60 Vdc 0....1000 A G14


PRODIGIT

Static Electronic DC Loads
Plug-in Modules for Mainframe

Model

Power W

Voltage V DC

Current A DC

3320

150

60

30

3321

300

60

60

3322

300

250

10

3324

200

500

5 (not suit for PFC)

3325

75

60

15